Rigel SafeTest 60 Electrical Safety Analyzer

Rigel SafeTest 60 Electrical Safety Analyzer
Product Specifications
BRAND  Rigel
MODEL  SafeTest 60
DESCRIPTION
Rigel SafeTest 60
An entry-level electrical safety analyzer for medical devices
  • Compact, robust and portable design
  • Fast step-through of test routines with minimised power breaks
  • Manual control of fault conditions
  • Large colour display with clear read-out
  • Tests to a range of international standards including IEC 60601, 62353, 61010 and NFPA-99
  • Insulation testing to IEC 62353
  • Accurate high current, low energy earth bond testing
Rigel SafeTest 60 Electrical Safety Analyzer
The Rigel SafeTest 60 is a robust, reliable and dedicated medical safety analyzer. It is ideal for testing high volumes of medical and laboratory equipment that does not require patient lead testing, such as beds, hoists, infusion pumps, CPAP’s and centrifuges etc.
With a large colour display and a colour-coded user interface, it’s easy to select the required tests with a single key press, whilst a fast step-through of the test routine makes the testing process speedy and dependable.
Whilst small, the SafeTest 60 includes a range of safety tests to enable compliance with a range of international safety standards, including leakage testing to IEC 60601, 62353, 61010 and NFPA-99, earth bond testing to 62353, 61010 and NFPA-99, and insulation testing to IEC 62353.

Technical Specification:
  • Earth Continuity
    • Method2 wire ZAP technique.
    • Test Current>±200mADC into 2Ω
    • Max Test Voltage4-24Vrms o/c
    • Measuring Range
    • (low range)0.001 – 0.999Ω / 0.001Ω resolution
    • Measuring Range
    • (mid range)1.00 – 9.99Ω / 0.01Ω resolution
    • Measuring Range
    • (high range)10.0 – 19.9Ω / 0.1Ω resolution
    • Accuracy± 1% of value, ± 5mΩ
    • Circuit ProtectionTest inhibited if ≥30VAC or DC at 4mm inputs
  • Powered Leakage Measurements
    • IEC 62353Equipment Leakage (Direct)
    • IEC / AAMI 60601Earth + Enclosure Leakage
    • NFPA-99Ground + Chassis Leakage
    • IEC 61010Touch Leakage, Touch Voltage
    • Test VoltageMains Supply Voltage
    • Measuring Range0.1μA to 9999μA
    • Accuracy± 2%, ± 5µA
    • Mains ReversalSoftkey
    • Single Fault ConditionsOpen neutral via softkey
    • Open earth via softkey
    • Frequency ResponseIEC 60601 - 62353, NFPA-99 and IEC 61010

Don't see the specific model you need?

Request supplier quotes.

KWIPPED is an equipment rental and leasing marketplace. Suppliers have additional inventory available not listed on KWIPPED.
Our quoting and collaboration platform is an incredibly easy and efficient way to source from our entire supplier network.
Get quotes

Not sure if you should rent or finance?

Tell us what you're thinking and will offer a recommendation.

We have equipment rentals and leases for all your medical needs

First time using KWIPPED?

We've made it really easy.

Here are some resources to get you started with your first rental