This high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button. Ideal for high-temperature industrial environments whether it's power utility, metal refining and smelting, glass, cement or petrochemical environments.
Features
- 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
- Multi-language interface (user select)
- Current Temperature plus MAX, MIN, DIF, AVG temperature displays
- Compatible with standard mini-connector K-type thermocouples
- Adjustable emissivity and predefined emissivity table
- Infrared and thermocouple temperature on backlit display
- Last reading Hold (20 seconds)
- High and low temperature alarm
- Data storage and review (99 data sets)
- Tripod mount
- 12 or 24 hour clock
- USB 2.0 computer interface cable
- FlukeView® Forms Documenting Software
Infrared Measurements
Temperature Range: -22 to 1652°F (-30 to 900°C)
IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C):
≥32°F: ±2°F or ±1% of the reading, whichever is greater
≥14°F to <32°F: ±4°F
<14°F: ±6°F
≥0°C: ±1°C or ±1 % of the reading, whichever is greater
≥-10°C to <0°C: ±2°C
<-10°C:±3 °C
IR Repeatability: ±0.5% of reading or ±1°F (±0.5°C), whichever is greater
Display Resolution: 0.1°F/0.1°C
Distance Spot: 60:1 (calculated at 90% energy)
Minimum Spot Size: 0.75" (19 mm)
Laser Sighting: Offset dual laser, output <1 mW
Spectral Response: 8 µm to 14 µm
Response Time: (95%)<500 ms
Emissivity: Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-Type Thermocouple Input Temperature Range: -454 to 2501°F (-270 to 1372°C)
K-Type Thermocouple Input Accuracy: <-40°F: ±(2°F + 0.2°/1°F)
≥-40°F: ±1% or 2°F, whichever is greater
<-40°C: ±(1 °C + 0.2°/1°C)
≥-40°C: ±1% or 1°C, whichever is greater
K-Type Thermocouple: 0.1°F/0.1°C
K-Type Thermocouple Repeatability: ±0.5% of reading or ±1°F (±0.5°C), whichever is greater
Measurement Options
Hi/Low Alarms: Audible and two-color visual
Min/Max/Avg/Dif: Yes
Switchable Celsius and Fahrenheit: Yes
Backlight: Two levels, normal and extra bright for darker environments
Probe Input: K-type thermocouple simultaneous display of probe and IR temperature
Trigger Lock: Yes
Data Storage: 99 points
Display: Dot matrix 98 x 96 pixels with function menus
Communication: USB 2.0
K-Type Thermocouple Specifications
Measurement Range (Bead Probe): -40 to 500°F (-40 to 260°C)
Accuracy: ±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C)
Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C)
Cable Length: 40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and Compliance: IEC 60825-1; FDA Laser Class II; IEC 61326-1; CE Complaint; CMC # 01120009
Operating Temperature: 32 to 122°F (0 to 50°C) Storage Temperature: -4 to 140°F (-20 to 60°C)
Relative Humidity: 10 to 90% RH non-condensing up to 86°F (30°C)